Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.usj.es/handle/123456789/383

Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorDíaz Pérez, F. J.-
dc.contributor.authorChinarro Vadillo, David-
dc.contributor.authorPino Otín, Rosa-
dc.contributor.authorGuardiola Mouhaffel, Ali Adib-
dc.date.accessioned2020-04-29T10:33:15Z-
dc.date.available2020-04-29T10:33:15Z-
dc.date.issued2018-
dc.identifier.citationDíaz Perez, F. J., Chinarro, D., Otín, M. R. P., Martín, R. D., & Mouhaffel, A. G. (2018). Reduction of energy consumption in hotels with aerothermal energy. case study: Canary islands (spain). International Journal of Engineering and Technology(UAE), 7(3), 127-131. doi:10.14419/ijet.v7i3.32.18412es_ES
dc.identifier.issn2227-524Xes_ES
dc.identifier.urihttps://repositorio.usj.es/handle/123456789/383-
dc.descriptionThis article presents a management model and control of energy efficiency in hotels adapted to the consumption patterns that ensure the comfort requirements of customers and integrated into the environment of an intelligent tourist complex. The analysis of the hot water system (DHW) of two hotels in the Canary Islands (Spain) in relation to their occupation, yields a solution based on renewable energies using high temperature heat pumps with aerothermal dissipation and supported by boilers of existing LPG propane. The control by programmable automatons (PLC) integrated in a system of control and acquisition of data (SCADA) optimizes the systems to maintain the maximum accumulated energy during the periods of cheapest electric tariff, by means of a system of opening and closing of hydraulic Valves that It manages to adjust the demand of DHW consumption to achieve the highest energy accumulation during the hours with the cheapest electricity tariff. The result after two and a half years of activity registration is a faster return on investment due to the optimized energy management of the system, through the control of operating hours adjusted to the needs of customers and the hourly rate. It has also been predicted that during the estimated 12 years of the system will have saved more than € 1,179,737 and thermal 8,780,005 kWh in a hotel 1 and € 1,315,104 and thermal 9,522,301 kWh in the hotel 2. This model shown can be seen how economically and energetically very efficientes_ES
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherScience Publishing Corporation Inces_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectEnergy efficiencyes_ES
dc.subjectHotelses_ES
dc.subjectAerothermal energyes_ES
dc.subjectSCADAes_ES
dc.subjectPLCes_ES
dc.subjectDHWes_ES
dc.titleReduction of energy consumption in hotels with aerothermal energy. Case study: Canary Islands (Spain)es_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.subject.unescoEnergía térmicaes_ES
dc.identifier.publicationfirstpage127es_ES
dc.identifier.publicationlastpage131es_ES
dc.identifier.doi10.14419/ijet.v7i3.32.18412es_ES
dc.rights.accessrightsinfo:eu-repo/semantics/openAccesses_ES
Aparece en las colecciones: Artículos de revistas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Reduction of energy consumption in hotels with aerothermal energy.pdf518,05 kBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons