Título : Modelling of energy and water supplies in hotels in lanzarote and fuerteventura with and without desalination plant (SWROP)
Autor: Díaz Pérez, F. J. ORCID RESEARCHERID SCOPUSID
Chinarro Vadillo, David ORCID RESEARCHERID SCOPUSID
Guardiola Mouhaffel, Ali Adib ORCID SCOPUSID
Díaz Martín, Ricardo ORCID SCOPUSID
Pino Otín, Rosa ORCID SCOPUSID
Palabras clave : Energy; Efficiency; Hotels; Modelling; nZEB; SWROP; Water
Fecha de publicación: dic-2016
Editorial : Indian Society for Education and Environment
Citación : Perez FJD, Chinarro D, Mouhaffel AG, Martin RD, Otin RP. Modelling of energy and water supplies in hotels in lanzarote and fuerteventura with and without desalination plant (SWROP). Indian J Sci Technol 2016;9(47):1-19.
Resumen : Objectives: This article presents a comparative study of energy and water consumption in four-star hotels in the Canary Islands (Spain), specifically on the islands of Fuerteventura and Lanzarote, with and without desalination sea water reverse osmosis plants (SWROP), of order to define a pattern of consumption based on the average occupancy rates of different establishments. Methods/Statistical Analysis: The method used for regression calculations of the data obtained has been, initially the data collection and filtration, perform the mean arithmetic of the data according to the intervals calculated, perform calculations and generate the correlation graphs of the different models, change the occupancy rates to a percentage and use all the values for the total calculation as if it were a single hotel, calculate the final model of energy and water consumption for establishments, and create a valid algorithm using the calculated regression models. Findings: We demonstrate the validity of the potential and polynomial models of regression used to calculate the approximate values for consumption of water, electricity and energy, valid for most of the hotels with an average occupancy rate of between 40% and 120%, which are typically the average occupancy rates for hotels in the Canary Islands during various months of the year. Through a calculated and demonstrated system of analysis, approximate simulations of consumption can be performed for hotels with the same or similar characteristics and modelling of reduced energy consumption can be performed by simulating occupancy values to test the level of reduction. Application/Improvements: The article concludes with the functions for the approximate calculations of energy consumption, electricity and water per guest, per day for hotels with similar characteristics to those in the study.
URI : https://repositorio.usj.es/handle/123456789/695
ISSN : 0974-6846
Aparece en las colecciones: Artículos de revistas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Modelling of Energy and Water Supplies in Hotels.pdf668,5 kBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons