Por favor, use este identificador para citar o enlazar este ítem: https://repositorio.usj.es/handle/123456789/500

Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.contributor.authorBlanco-Dominguez, Irene-
dc.contributor.authorDuch, Francesc-
dc.contributor.authorPolo, Vicente-
dc.contributor.authorAbad, Jose-
dc.contributor.authorGómez Barrera, Manuel-
dc.contributor.authorGarcia-Martin, Elena-
dc.date.accessioned2021-02-25T13:01:09Z-
dc.date.available2021-02-25T13:01:09Z-
dc.date.issued2020-09-11-
dc.identifier.citationBlanco-DominguezI, DuchF, Polo V,AbadJM, Gomez-Barrera M, Garcia-MartinE(2020)Correlationand regression analysisbetweenresidualgradationand uncorrectedvisualacuityone year after refractivesurgerywith LASIK,FS-LASIK,PRK,PRK Xtra techniquesand theimplantation of ICL®posteriorchamberphakiclensin myopiccorrection.PLoSONE 15(9):e0238399 https://doi.org/10.1371/journal.pone.0238399es_ES
dc.identifier.issn1932-6203es_ES
dc.identifier.urihttps://repositorio.usj.es/handle/123456789/500-
dc.description.abstractPurpose To analyze the influence of the final spherical equivalent (SE) in LogMAR uncorrected distance visual acuity (UDVA) one year after refractive surgery. We analysed refractive results, their predictability and efficacy, and the safety results of the different methods as secondary outcomes. Setting Refractive Surgery Unit of the Institut Català de Retina (ICR) in Barcelona, Spain. Design Retrospective, analytical observational study. Methods Retrospective and observational study of 654 eyes of 327 patients who underwent refractive surgery to treat their myopia or myopic astigmatism using LASIK, FS-LASIK, PRK, PRK Xtra or ICL-type lens implantation surgery were included. Results The correlation between the SE in absolute value was statistically significant in all techniques utilized, reaching higher values in the FS-LASIK and LASIK techniques, 0.774 and 0.706 respectively, and lesser values in PRK (0.480) and PRK Xtra (0.482). A significant adjustment via a univariate linear regression model could be implemented in all techniques, albeit the R2 coefficient of determination values were higher than those for the FS-LASIK (0.599) and LASIK (0.494) techniques. Conclusions There is a positive correlation between post-surgical SE value and post-operative LogMAR UDVA. These regression models can be adjusted to predict the final UDVA according to the final SE. The techniques that are most influenced by the final SE in terms of their visual results are FS-LASIK and LASIK.es_ES
dc.format.extent11 p.es_ES
dc.format.mimetypeapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherPublic Library Sciencees_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectIn-situ keratomileusises_ES
dc.subjectPhotorefractive Keratectomyes_ES
dc.subjectRisk-factorses_ES
dc.subjectRetreatmentes_ES
dc.subjectEctasiaes_ES
dc.titleCorrelation and regression analysis between residual gradation and uncorrected visual acuity one year after refractive surgery with LASIK, FS-LASIK, PRK, PRK Xtra techniques and the implantation of ICL® posterior chamber phakic lens in myopic correctiones_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.identifier.doi10.1371/journal.pone.0238399es_ES
dc.rights.accessrightsinfo:eu-repo/semantics/openAccesses_ES
Aparece en las colecciones: Artículos de revistas

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
Correlation and regression analysis between.pdf1,26 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está sujeto a una licencia Creative Commons Licencia Creative Commons Creative Commons